FUJITSU MPB3052AT User Manual

Page 22

Advertising
background image

C141-E045-02EN

1 - 7

(4)

Current fluctuation (Typ.) when power is turned on

Note:

Maximum current is 1.5 A and is continuance is 1.5 seconds

Figure 1.1

Current fluctuation (Typ.) when power is turned on

(5)

Power on/off sequence

The voltage detector circuit monitors +5 V and +12 V. The circuit does not allow a write
signal if either voltage is abnormal. This prevents data from being destroyed and eliminates
the need to be concerned with the power on/off sequence.