1 - 6

Table 1.3

Current and power dissipation

Typical RMS current (*1) [mA]

+12 V

+5 V

Model

MPB

3021AT

MPB

3032AT

MPB

3043AT

MPB

3052AT

MPB

3064AT

All Models

MPB

3021AT

MPB

3032AT

MPB

3043AT

MPB

3052AT

MPB

3064AT

Spin up

1300

1500 peak

460

600 peak

17.9

Idle (Ready)
(*3)

115

140

185

460

3.68

3.98

4.52

R/W (On Track)
(*4)

125

150

200

510

4.05

4.35

4.95

Seek (Random)
(*5)

335

360

410

510

6.57

6.87

7.47

Standby

4

155

0.82

Sleep

4

110

0.60

*1 Current is typical rms except for spin up.

*2 Power requirements reflect nominal values for +12V and +5V power.

*3 Idle mode is in effect when the drive is not reading, writing, seeking, or executing any

commands. A portion of the R/W circuitry is powered down, the spindle motor is up to
speed and the Drive ready condition exists.

*4 R/W mode is defined as 50% read operations and 50% write operations on a single

physical track.

*5 Seek mode is defined as continuous random seek operations with minimum controller

delay.

Typical Power (*2) [watts]

Mode of

Operation

Advertising