FUJITSU MPB3052AT User Manual

Page 42

Advertising
background image

C141-E045-02EN

3 - 11

06

B02

CSEL connected to the interface
Cable selection can be done by the
special interface cable.

B01

05

Figure 3.13 Jumper setting of Cable Select

Figures 3.14 and 3.15 show examples of cable selection using unique interface cables.

By connecting the CSEL of the master device to the CSEL Line (conductor) of the cable and
connecting it to ground further, the CSEL is set to low level. The device is identified as a
master device. At this time, the CSEL of the slave device does not have a conductor. Thus,
since the slave device is not connected to the CSEL conductor, the CSEL is set to high level.
The device is identified as a slave device.

Open

CSEL conductor

GND

Slave device

Master device

Host system

Figure 3.14 Example (1) of Cable Select

Slave device

Master device

CSEL conductor

GND

Host system

Open

Figure 3.15 Example (2) of Cable Select

Advertising