Upgrading the embedded bootloader, Upgrading the embedded bootloader -5, Section 4.2 – Freescale Semiconductor 802.15.4 User Manual

Page 31: 2 upgrading the embedded bootloader

Advertising
background image

Freescale Semiconductor Embedded Bootloader Reference Manual, Rev. 0.0

4-5

4.2 Upgrading The Embedded Bootloader

This section describes how to upgrade the Embedded Bootloader to a newer version with the P&E
Multilink BDM debugger.

1. Execute the HIWAVE.EXE file from your chosen installation directory. For example,

[installation directory]\Metrowerks\CodeWarrior_CW08_V3.0\Prog\

2. From the main window, setup the target by selecting Setup Target, the select the “Component” menu,

and click on “Set Target”. The “Set Target” window appears as shown in

Figure 16

.

Figure 16 Set Target Window

3. From the “Processor” drop down menu, select HCS08. From the “Target Interface” drop down menu,

select P&E Target Interface, then click the “OK” button.