1. MOUNTING

1-8

5. Position the signal cable so that no more than 4 cm of the sheath is exposed

as shown in the figure below. Tighten fixing bolts.

Sheath

CABLE GLAND

Plate

Gasket

Flat
washer

Bolt

Within 4 cm

Tubing

Shield

Figure 1-12 How to fix signal cable in cable gland

6. Unfasten four screws shown in the figure below.

Four screws

Figure 1-13 Antenna unit chassis, cover opened

7. Pass the signal cable through the cable protector.

Cable
protector

Figure 1-14 Antenna unit chassis, cover opened

8. Connect the signal cable to the RTB Board (03P9249), referring to the

interconnection diagram and the figure below.