Wiring, 1 connections, Caution – Furuno 851 MARK-2 User Manual

Page 18

Advertising
background image

2-1

2. WIRING

2.1 Connections

Connect the signal and power cables, the ground wire and optional equipment as
shown in Figure 2-1.

OPTION

HDG

NMEA

DJ-1

OPTION

MARINE RADAR

TYPE
SER.NO.
DATE
COMPASS SAFE DISTANCE
STD

M STEER

M

EQUPMENT CLASS
FURUNO ELECTRIC CO., LTD

10.2-31.2VDC

3 GND

1

2

Signal cable connector

Connect signal cable

from antenna here.

NMEA connector
Connect navaid
here.

HDG connector
Connect heading
sensor here.

Power cable connector

Connect power

cable here.

Ground terminal
Connect ground wire between
here and ship's ground.

OPTION connector
Connect navaid,
echo sounder or
external buzzer here.

CAUTION

Tighten the boot-band
securely to ensure
watertightness.

CAUTION

For 24 volt power,
replace fuse with 5A
fuse (supplied), and
attach "5A fuse label"
to the fuse cover on
power cable.
Factory setting is 10A
for 12 VDC set.

See next page.

OPTION connector
Connect remote
display here.

*2

*3

*1

Signal cable
S03-83

Figure 2-1 Display unit, rear view

*1:The following cables are supplied with remote display.
Type

Code no.

Remarks

FM-C10FPD002-050

000-143-894

5m

FM-C10FPD002-100

000-143-893

10m

FM-C10FPD002-150

000-143-892

15m

Advertising