1.

2.

3.

4.

5.

ELECTRIC SHOCK HAZARD

WARNING

Turn off electric power before service or

installation.

Failure to do so may result in personal injury,

or death.

Sealed Refrigeration System contains refrigerant

and oil under high pressure.

Proper safety procedures must be followed,

and proper protective clothing must be worn

when working with refrigerants.

Failure to follow these procedures could

result in serious injury or death.

WARNING

HIGH PRESSURE HAZARD

The use of nitrogen requires a pressure

regulator. Follow all safety procedures and

wear protective safety clothing etc.

Failure to follow proper safety procedures

result in serious injury or death.

WARNING

EXPLOSION HAZARD

Recover all refrigerant and oil from the system.

Remove compressor, capillary tube and filter drier

from the system.

Flush evaporator condenser and all connecting

tubing with dry nitrogen or equivalent. Use approved

flushing agent to remove all contamination from

system. Inspect suction and discharge line for

carbon deposits. Remove and clean if necessary.

Ensure all acid is neutralized.

Reassemble the system, including new drier strainer

and capillary tube.

Proceed with step 9-10 above. (see page #22).

SPECIAL PROCEDURE IN THE CASE OF MOTOR

COMPRESSOR BURNOUT

Basically, troubleshooting and servicing rotary compres-

sors is the same as on the reciprocating compressor with

only one main exception:

NEVER, under any circumstances, charge a rotary com-

pressor through the

LOW side. Doing so would cause

permanent damage to the new compressor.

ROTARY COMPRESSOR SPECIAL TROUBLESHOOTING

AND SERVICE

22

Advertising
This manual is related to the following products: