Warning, Notice, Electrical data – Friedrich 2008 User Manual

Page 8: Plug/outlet/circuit rating

Advertising
background image

eleCTRICAl DATA

ELECTRIC SHOCK HAZARD

WARNING

Turn off electric power before service or

installation.

All electrical connections and wiring MUST be

installed by a qualified electrician and conform to

the National Electrical Code and all local codes

which have jurisdiction.
Failure to do so can result in personal injury or

death.

Not following the above WARNING could result in fire or

electically unsafe conditions which could cause moderate

or serious property damage.
Read, understand and follow the above warning.

NOTICE

FIRE HAZARD

Wire Size

Use ONLY wiring size recommended for single outlet branch circuit.

Fuse/Circuit Breaker

Use ONLY the correct HACR type and size fuse/circuit breaker. Read electrical ratings on unit’s

rating plate. Proper circuit protection is the responsibiity of the homeowner.

Grounding

Unit MUST be grounded from branch circuit through service cord to unit, or through separate

ground wire provided on permanently connected units. Be sure that branch circuit or general

purpose outlet is grounded. Ground wire must be connected to ground screw located in lower

right corner of air conditioner when air conditioner is in cabinet. (CP 14, 18, 24)

Receptacle

The field supplied outlet must match plug on service cord and be within reach of service cord.

Do NOT alter the service cord or plug. Do NOT use an extension cord. Refer to the table above

for proper receptacle and fuse type.

Plug/Outlet/Circuit Rating

Model

Circuit Rating

Breaker or T-D Fuse

Plug Face

(NEMA#)

Power Cord

Length (ft.)

Wall Outlet

Appearance

CP14

125V - 15A

5 - 15P

6

CP18

250V - 15A

6 - 15P

4

CP24

250V - 20A

6 - 20P

4

6