COOlING ONlY ROOM AIR CONDITIONeRS: TROUBleSHOOTING TIPS

n

o

it

c

A

e

s

u

a

C

e

l

b

i

s

s

o

P

m

e

l

b

o

r

P

Compressor
does not run

Low voltage

Check voltage at compressor. 115V & 230V
units will operate at 10% voltage variance

T-stat not set cold enough or
inoperative

Set t-stat to coldest position. Test t-stat & re-
place if inoperative

Compressor hums but cuts off on
overload

Hard start compressor. Direct test compressor.
If compressor starts, add starting components

Open or shorted compressor
windings

Check for continuity & resistance

Open overload

Test overload protector & replace if inoperative

Open capacitor

Test capacitor & replace if inoperative

Inoperative system switch

Test for continuity in all positions. Replace if
inoperative

Broken, loose or incorrect wiring

Refer to appropriate wiring diagrams to check
wiring

n

o

it

c

A

e

s

u

a

C

e

l

b

i

s

s

o

P

m

e

l

b

o

r

P

Fan motor

does not run

Inoperative system switch

Test switch & replace if inoperative

Broken, loose or incorrect wiring

Refer to applicable wiring diagram

Open capacitor

Test capacitor & replace if inoperative

Fan speed switch open

Test switch & replace if inoperative

Inoperative fan motor

Test fan motor & replace if inoperative (be sure
internal overload has had time to reset)

n

o

it

c

A

e

s

u

a

C

e

l

b

i

s

s

o

P

m

e

l

b

o

r

P

Does not cool or

only cools slightly

Undersized unit

Refer to industry standard sizing chart

T-stat open or inoperative

Set to coldest position. Test t-stat & replace if
necessary

Dirty fi

l

a

u

n

a

M

s

’r

e

n

w

O

n

i

d

e

d

n

e

m

m

o

c

e

r

s

a

n

a

e

l

C

r

e

tl

Dirty or restricted condenser or
evaporator coil

Use pressure wash or biodegradable cleaning
agent to clean

Poor air circulation

Adjust discharge louvers. Use high fan speed

Fresh air or exhaust air door open
on applicable models

Close doors. Instruct customer on use of this
feature

Low capacity - undercharge

Check for leak & make repair

Compressor not pumping properly

Check amperage draw against nameplate. If
not conclusive, make pressure test