COOlING ONlY ROOM AIR CONDITIONeRS: TROUBleSHOOTING TIPS

n

o

it

c

A

e

s

u

a

C

e

l

b

i

s

s

o

P

m

e

l

b

o

r

P

Compressor runs

for short periods

only. Cycles on

overload

Overload inoperative. Opens too
soon

Check operation of unit. Replace overload if
system operation is satisfactory

Compressor restarted before
system pressures equalized

Allow a minimum of 2 minutes to allow
pressures to equalize before attempting to
restart. Instruct customer of waiting period

Low or uctuating voltage

Check voltage with unit operating. Check for
other appliances on circuit. Air conditioner
should be in separate circuit for proper voltage
& fused separately

Incorrect wiring

Refer to appropriate wiring diagram

Shorted or incorrect capacitor

Check by substituting a known good capacitor
of correct rating

Restricted or low air ow through
condenser coil or evaporator coil

Check for proper fan speed or blocked
coils

Compressor running abnormally

hot

Check for kinked discharge line or restricted
condenser. Check amperage

n

o

it

c

A

e

s

u

a

C

e

l

b

i

s

s

o

P

m

e

l

b

o

r

P

T-stat does not

turn unit on

Loss of charge in t-stat bulb

Place jumper across t-stat terminals to check if
unit operates. If unit operates, replace t-stat.

Loose or broken parts in t-stat

Check as above

Incorrect wiring

Refer to appropriate wiring diagram

Defective thermistor

Replace thermistor or electronic control board

n

o

it

c

A

e

s

u

a

C

e

l

b

i

s

s

o

P

m

e

l

b

o

r

P

Noisy operation

Poorly installed

Refer to Installation Manual for proper
installation

Fan blade striking chassis

Reposition - adjust motor mount

Compressor vibrating

Check that compressor grommets have not
deteriorated. Check that compressor mounting
parts are not missing

Improperly mounted or loose
cabinet parts

Check assembly & parts for looseness,
rubbing & rattling

n

o

it

c

A

e

s

u

a

C

e

l

b

i

s

s

o

P

m

e

l

b

o

r

P

Water leaks into

the room

Evaporator drain pan over owing

Clean obstructed drain trough

Condensation forming on base pan

Evaporator drain pan broken or cracked.

Reseal or replace. No chassis gasket installed.

Install chassis gasket

Poor installation resulting in rain
entering the room

Check installation instructions. Reseal as
required

Condensation on discharge grille
louvers

Dirty evaporator coil. Use pressure wash

or biodegradable cleaning agent to clean.

Environmental phenomena: point supply

louvers upward

Chassis gasket not installed

Install gasket, per Installation manual

Downward slope of unit is too
steep inward

Refer to installation manual for proper
installation