Satellite-fill icemaker ventilation and exhaust requirements

Fabricator-supplied, custom air intake grilles must have 12" x 12" (305mm x 305mm) opening yielding 100 sq.
inches (645 sq. cm) of open air space within duct perimeter. Block off any open area outside of the air duct.

Intake air requirements — air-cooled icemakers (MCD400AHS, MCD400AVS & R400A only)

1. Check that 2" (51mm) duct is installed on condenser front.

2. Cut a 12" x 12" (305mm x 305mm) opening in counter face to align with duct.

3. Position icemaker to mate duct flush with back of counter opening.

4. Install supplied grille on outside of counter opening.

Exhaust air — all icemakers (MCD400A/W & R400A/W)

Provide 100 sq. in. (645 sq. cm) of counter opening for exhaust air at least 18" (457mm) from intake opening
but not more than 10 ft (3m) away.

Air in
through louver

Standard 51mm
(2") duct
mates counter
opening
(behind grille) to
condenser front

Exhaust air
out side to
opening at least
457mm (18" )
from air intake

Air out through louver

Provide at least 645 sq. cm
(100 sq. inches) of counter
opening for exhaust air

Exhaust air

Air intake

Standard
louvered grille
(supplied)

Supplied 2" (51mm) duct MUST be installed
to front of icemaker and mated flush to inside
of counter face opening.

MCD400AHS, MCD400AVS & R400A — Side View

Front View

Advertising