Technical specifications (all models), Air-cooled icemaker refrigeration pressure, Water-cooled icemaker refrigeration pressure – Follett T400A/W User Manual

Page 19

Advertising
background image

condenser

filter dryer

thermostatic

expansion

valve

evaporator

high side

service port

low side

service port

high pressure

switch

compressor

high

pressure

vapor

low

pressure

vapor

high

pressure

liquid

low

pressure

liquid

19

Technical specifications (all models)

Refrigeration system diagram

Refrigeration pressure data

Notes: 1) Water regulating valve is factory set at 225 PSIG head pressure.

2) Readings within 10% of above table values should be considered normal.

Ambient air temperature ˚F/˚C

Icemak

er inlet w

ater temper

ature ˚F/˚C

˚F/˚C

50/10

70/21

90/32

60/16

174/23

174/23

190/25

80/27

245/31

244/30

265/32

100/38

237/37

326/38

347/40

Air-cooled Icemaker
Refrigeration Pressure

Discharge Pressure/Suction Pressure

psi

psi

psi

Condenser inlet water temperature ˚F/˚C

Icemak

er inlet w

ater temper

ature ˚F/˚C

˚F/˚C

50/10

70/21

90/32

50/10

236/28

237/28

236/28

70/21

235/29

230/30

235/30

90/32

250/34

250/34

250/34

Water-cooled Icemaker
Refrigeration Pressure

Discharge Pressure/Suction Pressure

psi

psi

psi

Compressor data

Compressor current draw

Air-cooled
Ambient air temp.

60˚F/15.6˚C

70˚F/21.1˚C

80˚F/26.7˚C

90˚F/32.2˚C

100˚F/37.8˚C

6.3A 6.5A 6.7A 6.9A 7.1A

Water-cooled
Water temp. at float

50˚F/10˚C

60˚F/15.6˚C

70˚F/21.1˚C

80˚F/26.7˚C

90˚F/32.2˚C

6.6A 6.7A 6.7A 6.8A 6.9A

Locked rotor amps 58.8