Specifications, Electrical, Electrical connections plumbing – Follett T400A/W User Manual

Page 5: Ambient

Advertising
background image

5

Specifications

Electrical

Each icemaker and dispenser require a separate circuit with electrical disconnect within 10 ft (6m).
Equipment ground required.
Standard electrical – 115V, 60Hz, 1 phase.
Maximum dispenser fuse – 15 amps,
Maximum icemaker fuse – 20 amps each
Maximum icemaker amperage – 11 amps each
Cord and plug provided on icemaker and dispenser

Model

Electrical connection

Circuits required

25FB400A/W, 50FB400A/W, 110FB400A/W

cord & plug provided

115/60/1, 20 amp max. fuse size

25CT400A/W, 50CT400A/W, 110CT400A/W

cord & plug provided

115/60/1, 20 amp max. fuse size

25CR400A/W, 50CR400A/W, 110CR400A/W

dispenser, icemaker

115/60/1, (2) circuits required

and bin signal:

dispenser: 15 amp max. fuse size

cord & plug provided

icemaker: 20 amp max. fuse size

VU155R400A/W, VU300R400A/W

dispenser, icemaker

115/60/1, (2) circuits required

VU155BR400A/W, VU300BR400A/W

and bin signal:

dispenser: 15 amp max. fuse size

VU155R400A/WX, VU155BR400A/WX

cord & plug provided

icemaker: 20 amp max. fuse size

VU155NR400A/W, UD300R400A/W

dispenser, icemaker

115/60/1, (3) circuits required

VU155R800A/W, VU300R800A/W,

and bin signal:

VU155R800A/WX,

cord & plug provided

dispenser: 15 amp max. fuse size

VU155BR800A/W, VU300BR800A/W,

(2) icemakers: 20 amps max. fuse

VU155R800A/WX

size

each

Electrical connections

Plumbing

3/8" OD push-in water inlet
3/4" MPT drain
3/8" FPT condenser inlet (water-cooled condenser only)
3/8" FPT condenser drain (water-cooled condenser only)

Notes: Slope to drain of 1/4" per foot (6mm per 30.4cm run) with a 1/2" min. is recommended.

Water shut-off recommended within 10 feet (3m), drain to be hard piped and insulated.

Separate drains for icemaker and condenser. To prevent back flow, do NOT connect drains.

Follett recommends installation of an activated carbon filter in icemaker inlet water line.

Ambient

Air temperature

100˚ F/38˚ C max.

50˚F/10˚C min. (best performance below 80˚F/27˚C)

Water temperature

90˚F/32˚C max.

40˚F/4˚C min. (best performance below 70˚F/21˚C)

Water pressure

70 P.S.I max. (482 kPA)

10 P.S.I. min. (89 kPA)

Advertising