Follett T400A/W User Manual

Page 26

Advertising
background image

26

Diagnostic sequence – Stage 10

If the water level in the float reservoir drops to an unacceptable level, the WTR LED will go out, shutting the
icemaker off. Also, the BT LED will come on, preventing the icemaker from restarting for twenty minutes. If water
is restored, the WTR LED will come back on and flash to alert the technician that water to icemaker has been
lost. The icemaker will then restart at the end of the 20 minute time delay. The flashing WTR LED can be cleared
by pressing the reset button.

GRD

L1
L1
L2

L2
L2

L2
L2

COMPRESSOR
FAN
DRIVE

DR

C

20M

60M

2ND

WTR

B-T

B-E

RESET

X

GRD

G

B

W

FAN

BLACK

WHITE

BLACK

BLACK

R

ORANGE

S

S

L

COMPRESSOR

C

RED

BLACK

BLACK

WHITE

INPUT

POWER

WATER

SENSOR

CONTROL
BOARD

B

LA
CK

GEARMOTOR

2

4

V

COMMO

N

LI

N

E

V

AC

RED

RED

W
HITE

BLA

C

K

BIN T-STAT

BIN SIGNAL
FROM DISPENSER
JUNCTION BOX
(MCD400A/WVS series –
blk wire is on 24V)

WHITE

RED

WHITE

M

1

COMPRESSOR

SWITCH

PWR

BLACK

T.O.L.

BLACK

RED

HIGH PRESSURE
SAFETY SWITCH

4

2

3

RUN

START

T.O.L.

B

LUE

YELLOW

BLACK

WHITE

M

Advertising
This manual is related to the following products: