G7945/G7946 Radial Drill Press

Figure 3. Typical type 5-15 plug and receptacle.

Serious personal injury could occur if you

connect the machine to the power source

before you have completed the set up pro-

cess. DO NOT connect the machine to the

power source until instructed to do so.

110V Operation

Amperage Draw

The

1

2

HP motor on the Model G7945/G7946 will

draw the following amps:

Motor Draw ..............................................5 Amps

Circuit Requirements

Whether you have a dedicated or shared circuit,
ONLY connect your machine to a circuit with
a verified ground, correctly sized wiring, and a
properly rated circuit breaker. Obey all applicable
safety and electrical codes, including the National
Electric Code (NEC).

If you are unsure about

any wiring practices, consult a qualified elec-

trician.

Minimum Circuit Requirement .................10 Amp

Plug/Receptacle Type

Included Plug Type ........................... NEMA 5-15

This machine must have a ground prong in

the plug to help ensure that it is grounded.

DO NOT remove ground prong from plug

to fit into a two-pronged outlet! If the plug

will not fit the outlet, have the proper outlet

installed by a qualified electrician.

Extension Cords

We do not recommend the use of extension
cords. If you find it absolutely necessary to use
an extension cord with your machine:

Use at least a 14 gauge cord that does not
exceed 50 feet in length!

The extension cord must also contain a
ground wire and plug pin.

A qualified electrician MUST size cords over
50 feet long to prevent motor damage.