PRE-INSTALLATION CHECKS

Model

Flue/Chimney Size

Without liner system (round)

minimum dimension (diameter.)

mm

200

200

200

200

200

inch

8

8

8

8

8

Without liner system (square)

minimum dimension

mm

185

185

185

185

185

inch

7 1/4

7 1/4

7 1/4

7 1/4

7 1/4

Liner or factory made system

(diameter.)

installed in accordance with manufacturers instructions

mm

200

200

200

200

200

inch

8

8

8

8

8

Do not connect to systems containing large voids or over 9" (230mm) square/round

Flue/Chimney

minimum height*

All Products

m

4.5

4.5

4.5

4.5

4.5

feet

15

15

15

15

15

* When measured from the top of the appliance to the top of the flue, with no horizontal sections

and a maximum of 4 bends with angles of less than 45°

16"

Riva

Open

22"

Riva

Open

24"

Riva

Open

26"

Riva

Open

28"

Riva

Open

17

1.1 This appliance requires ventilation to supply combustion air.

Any room containing the appliance must have a permanent

air vent opening with a total free area of at least 550mm

2

per kW of appliance rated output above 5kW.

1.2 Increase air supply provisions where a room contains

multiple appliances.

1.3 If vents open into adjoining rooms or spaces there must be

an air vent of at least the same size direct to the outside.

1.4 Permanent air vents should be non-adjustable and

positioned where they are unlikely to become blocked.

1.5 Site the vents where cold draught is unlikely to cause

discomfort. This can be avoided by placing vents near

ceilings or close to the appliance, see Diagram opposite.

1. VENTILATION