1. ANNUAL SERVICE

1.1 Before the start of the heating season strip, inspect and

clean the appliance as detailed:

• Allow appliance to cool


• Remove all of the following internal parts; damper system,

complete log box/multi-fuel box/cast basket

• Remove any frames, Installation Section 3

• Sweep the appliance at this point if it is required

• Vacuum clean any remaining ash and debris from the

inside of the appliance


Stovax offer a filter/collection attachment for your vacuum

cleaner to protect it from fire ash. Ash Clean (Stovax Part

No. 2091).

• Clean the internal surfaces of the appliance using a wire

brush and scraper as required

Vacuum and brush the resulting debris from the appliance.


• Clean the grate parts with a wire brush, and check the

parts for any damage

• Replace any damaged parts

• Re-fit cleaned internal parts

• Lightly oil any operating mechanisms

To refresh painted finishes use Stovax Thermolac paint.

1.2 Use genuine Stovax replacement parts to keep your

appliance in safe and efficient working order. Your local

Stovax dealer can provide you with the parts you require.

This is a list of the maintenance products you may need to use

Task

Product name

Stovax Code

Number

Preventing build-

up of creosote in

flue

Protector (15 sachets)

7002

Protector (1kg tub)

7025

Sealing flue pipe

joints

Fire Cement (500g tub)

2020

Fire Cement (600g cartridge)

2021

Re-painting

Thermolac Black
(400ml aerosol)

2019

Thermolac Black
(200ml brush-on)

2057

Cleaning matt

black Appliances

Colloidal black (85ml)

7000

Protecting your

hands

Heat resistant leather gloves

4008

Ash Clean

Vacuum Cleaner Attachment

2091

These products, available from your local Stovax dealer,

along with regular maintenance and use of correct fuels, will

keep your appliance in the best possible condition.

1.3 If you require more information about Stovax group

products visit our web site www.stovax.com

1.4 Using the appliance for the first time:

• Burn at a low output for the first day of use

This allows the seals and paint to fully cure.

1.5 During this time the appliance may give off some

unpleasant odours:

• Keep the room well ventilated to avoid a build-up of

fumes.

1.6 Your Stovax dealer can carry out service and maintenance.

2. FITTING AND REMOVAL OF

FLUE DAMPER

2.1 See Section 6 Fitting & Removal of Flue Damper in

Installation section.

MAINTENANCE and SERVICING

For a complete list of spare parts and accessories contact your Stovax dealer for the

Stovax Fireplace, Stove & Hearth Accessories brochure or call 01392 474011