2.2 Extractor fans or cooker hoods should not be placed in the

same room or space as the appliance.

2.3 If any of these checks reveal problems do not proceed

with the fitting of the appliance until they have been

rectified.

2.1 Open appliances require additional ventilation to comply

with the requirements of the Building Regulations. This

should be provided using a permanently open air vent, of

the size listed, which is positioned so that it is not liable to

be blocked both inside and outside the building.

Model

Additional Ventilation

mm2

14400

16538

19215

21735

21735

cm2

144

165

192

217

217

in2

22.32

25.63

29.78

33.69

33.69

16"

Riva

Open

22"

Riva

Open

24"

Riva

Open

26"

Riva

Open

28"

Riva

Open

2. ADDITIONAL VENTILATION

PRE-INSTALLATION CHECKS