Troubleshooting continued – Garland SH/IN 5000 User Manual

Page 23

Advertising
background image

Part # 4520898 (03/31/11)

Page 23

TROUBLESHOOTING continued

Malfunction With Error Code

Number of Flashing

Signals (Code)

Possible Cause

Action To Take By Operator Or Operating

Personnel

E03

- . . . - . . .

Overheated heat sink

Let unit cool down

Check air filter and air flow

Air-cooling system obstructed

Verify that air inlet and air outlet are not

obstructed with objects

Clean air filter

E04

- . . . . - . . . .

Overheated cooking zone

Let unit cool down

Check air filter and air flow

E06

- . . . . . . - . . . . . .

Overheated electronic

Let unit cool down

Check air filter and air flow

Ambient temperature too high (the cooling

system is not able to keep the cooker in normal

operating conditions 1)

Verify that no hot air is sucked in by the fan.

Reduce the ambient temperature. The air inlet

temperature must be lower than 104°F/40°C

E07

- . . . . . . . - . . . . . . .

Empty cooking sensing element activated

Reset empty cooking protection by switching

the unit off

E08

- . . . . . . . . - . . . . . . . .

Ambient temperature beyond operating range Make sure that the operating conditions

(especially the ambient temperature) are kept

Error on sensing element

Contact service agent

Order of error message: The indicator lamp lights up for an interval of 0.6 sec. The number of the following short flashes has to be

counted and informs about the kind of error corresponding to the above mentioned code system.

The code will repeat until the error is cancelled.

1 The cooling-system (fan) starts to operate when the ambient temperature in the control area exceeds 131°F/55°C. At heat

temperatures higher than 158°F /70°C the controller automatically reduces the power to keep the unit in normal operating

conditions. The cooker runs in a non continuous mode. This mode can be heard.

Advertising
This manual is related to the following products: