Trouble shooting

Malfunction

Cause

Remedial action

ADD BEANS is

displayed despite

a full bean container

Grinder has still not been

filled automatically.

Press the n button.

a full bean container. The beans are too big or too

oily - they do not slide into

the grinding unit.

Use less oily or smaller

beans. To remove big beans

use a vacuum cleaner.

No hot water or

steam discharge.

Nozzle is blocked.

Thoroughly clean nozzle.

Froth insufficient or

too runny.

Sleeve a on nozzle 12 not in

correct position.

Push down sleeve a

on nozzle 12.

Unsuitable milk.

Use cold semiĆskimmed milk.

Coffee is running

a drop at aĂtime.

Degree of grinding too fine.

Select a coarser degree of

grinding.

The beans are too oily.

Use less oily beans.

Preground coffee too fine.

Use a coarser ground coffee.

To rinse the appliance,

follow the instructions Using

ground coffee" on page 14,

but do not add coffee

powder in the duct.

Coffee has no

crema"

Unsuitable type of coffee.

Change the type of coffee.

crema"

(layerĂof froth).

Beans no longer fresh.

Use fresh beans.

(layerĂof froth).

Degree of grinding not

appropriate for coffee beans.

Optimize degree of grinding.

Grinding unit is not

grinding coffee

beans.

Beans are not falling into

the grinding unit (too oily).

Gently tap the bean

container.

Descaling program

does not start.

Current programming set to:

FILTER YES/NEW or

CHANGE FILTER

display.

Set programming to

FILTER NO/OLD ć

Before descaling

the appliance, always remove

the filter.

System too hot.

Draw off some of the hot

water.