Installation instructions, Site requirements – Stovax Riva Nemos 8627 MA User Manual

Page 10

Advertising
background image

10

1C

AR1673

2.1 TOP FLUE UP & OUT KIT (8534/8534AN)

Vertical from the top of the appliance then horizontally out.

(See diagram 1A). The basic kit comprises:

1 x 200mm vertical length

1 x 500mm terminal length (cut to length on site)

1 x 90 degree elbow

1 x wall plate

1 x 70mm restrictor

1 x 60mm restrictor fixing screws

The kit may be used on its own. (Note – with a 200mm rise

only the 500mm terminal length can be used). Extra lengths

may be added to the vertical and horizontal from the list

below.

2.2 TOP FLUE UP & OUT WITH ADDITIONAL

BEND

Any additional bend may be used on the horizontal section

(either 45° or 90°), but the overall horizontal flue run will be

reduced. Refer to diagram 1B.

2. FLUE OPTIONS

1A

AR1671

Start of bend to centre line of horizontal flue 170mm. Centre line

of vertical flue to end of bend 220mm.

1B

AR1672

INSTALLATION INSTRUCTIONS

SITE REQUIREMENTS