Installation instructions, Site requirements – Stovax Riva Nemos 8627 MA User Manual

Page 9

Advertising
background image

9

INSTALLATION INSTRUCTIONS

SITE REQUIREMENTS

1. FLUE AND CHIMNEY REQUIREMENTS

NOTE: This appliance can only be installed in conjunction

with the flue supplied.

1.1 The flue must be sited in accordance with all local and

national regulations and current rules in force.

1.2 Any terminal which is less than 2 metres above any access

(level ground, balcony or above a flat roof to which people

have access) is to be fitted with a guard.

1.3 All vertical and horizontal flues must be securely fixed and

fire precautions followed in accordance with local and

national codes of practice.

1.4 A restrictor may be required. Refer to Technical

Specifications on page 8.

1.5 Two types of flue terminals are available, horizontal and

vertical. For a horizontal terminal, decide on the terminal

position and measure the height from the top of the

appliance to the centre of the required hole. For minimum

and maximum flue dimensions see Section 2.

1.6 Only the horizontal terminal section can be reduced in size.

TIMBER FRAMED BUILDINGS

1.7 It will be necessary to provide additional clearance when

the flue passes through a wall containing any combustible

materials so as to prevent a fire hazard.

1.8 The hole through which the flue will pass, must have a steel

sleeve which is positioned so that an air gap of at least

25mm is maintained between the outer surface of the flue,

and any part of the sleeve.

1.9 For further guidance on the installation of gas appliances in

timber framed buildings, contact your local buildings control

authority.