d) Remove the external feed pipe from the brass fitting. See

diagram 8 arrow B.

e) Remove the 2 screws fixing the valve bracket to the base

of the appliance.

f) Gently slide the gas valve and bracket forward and

disconnect the thermocouple from the rear of the gas valve.

See diagram 9, arrow A.

9

AR0824

g) Push the thermocouple down through the hole in the

base of the firebox and remove the component.

3.7 When fitting the new component after it has been shaped

to the old thermocouple, push the tip (pilot end) through

the hole from under the firebox floor. Do not insert the tip

into the pilot burner at this stage.

3.8 Connect the thermocouple at the gas valve, do not over

tighten the nut.

3.9 Assemble the gas valve bracket on to the firebox base and

all pipes to the valve and fittings.

3.10 Insert the tip of the thermocouple into the pilot burner and

tighten the nut. Replace the silicone around the

thermocouple and ignition lead. Screw the plate into

position, replace the pilot cover, log support and replace

the ceramics.

4. IGNITION LEAD

4.1 Remove the screw from the left-hand side of the control

cover. On the right hand side of the cover is a locking tab,

this must be gently levered off the main body. Slide the

cover forward. See diagram 10.

AR0916

10

4.2 Pull the ignition lead off the piezo. Remove the burner as

described in section 2, pilot cover and plate as described in

section 3.

4.3 Disconnect the ignition lead from the electrode and

push the lead complete with the vidaflex through the base

of the appliance.

4.4 Cut the cable tie and remove the vidaflex sleeve. THIS

MUST BE KEPT AND ASSEMBLED ON THE NEW LEAD. A

CABLE TIE MUST ALSO BE USED TO RETAIN THE SLEEVE.

4.5 The lead can only be fitted one way round, ensure this is

correct when refitting a replacement.

4.6 When replacing the cover plate ensure silicone sealant is

used to seal the aperture.

5. PIEZO

5.1 The piezo assembly used on this appliance is not

serviceable and is unlikely to fail.

5.2 If a new piezo is required it will be necessary to change the

gas valve. Refer to section 6.

6. GAS VALVE

6.1 Turn the gas supply off at the isolation elbow, and

disconnect from the inlet pipe on the fire.

6.2 Disconnect the feed pipe and pilot pipe from the brass

fittings. See diagram 11.

11

AR0822

SERVICING INSTRUCTIONS