Pre-installation checks, Flue, Additional ventilation – Stovax Riva Plus Midi Wood & Multi-fuel User Manual

Page 17

Advertising
background image

17

PRe-INsTAllATIoN CHeCKs

1. FlUe

Model

:

Riva Plus Small RVP-SMM/RVP-SMW

Riva Plus Large RVP-LAM/RVP-LAW

Riva

Traditional

small

RVP-SMM/RVP-SMW

Riva

Traditional

large

RVP-LAM/RVP-LAW

Flue/Chimney Size

Without flue liner Round (diameter)

mm

150

150

inch

6

6

Without flue liner system Square

(diameter)

mm

135

135

inch

5

1

/

2

5

1

/

2

With liner or Factory made system

(diameter)

installed in accordance with manufacturer's instructions

mm

†150

†150

inch

†6

†6

Flue/Chimney

(*minimum height)

All products

metre

4.5

4.5

feet

13

13

* When measured from the top of the stove to the top of the flue, with no

horizontal sections and a maximum of 4 bends with angles of less than 45o

†May be 125mm (5") if only burning low volatiles (smokeless) fuels approved for use in Smoke Control Areas.

See website http://uksmokecontrolareas.co.uk for more information about approved fueld

2.1 Additional ventilation is required to comply with the

requirements of the Building Regulations. This must be

provided using a permanently open air vent, of the size

listed, which is positioned so that it is not liable to be

blocked both inside and outside the building.

2.2 Extractor fans or cooker hoods must not be placed in the

same room or space as this can cause the appliance to emit

fumes into the room.

2.3 If any of these checks reveal problems do not proceed

with the fitting of the appliance until they have been

rectified.

2. AddITIoNAl VeNTIlATIoN

Model

:

Riva Plus Small RVP-SMM/RVP-SMW

Riva Plus Large RVP-LAM/RVP-LAW

Riva

Traditional

small

RVP-SMM/RVP-SMW

Riva

Traditional

large

RVP-LAM/RVP-LAW

Additional Ventilation

mm

2

NONE

3300

cm

2

NONE

33.0

in

2

NONE

5.12