INsTAllATIoN INsTRUCTIoNs

PR8054

All models

Flue pipe x 612 long

Seal Collar with

fire cement

Self tapping screws

2.2 Connect a flue pipe 612mm long by inserting it into the flue

spigot and seal using fire cement. Fit the cast iron finishing

collar over the flue pipe and locate into recess in the top

cover

PR8052

Connection to chimney as detailed

in Building Regulations

135 Elbow with

access cover

Flue Pipe x 612 long

600mm

minimum

1000mm

max

unsupported

All Models

3. ReAR FlUe INsTAllATIoN

Because the stove is supplied for top flue exit, you need to

move the blanking plate to the top of the appliance and the

fit the collar and flue pipe to the rear:

3.1 (Tools required - cross-headed screw driver, 10mm A/F

spanner/socket wrench and a key hole saw).

• Remove the flue break-out cover using a small key hole

saw to cut the 3 securing lugs

PR8064

3 Small Lugs

Cut Using

Saw

3.2 To change from top to rear exit flue, reverse the flue spigot

and blanking plate using the method detailed.

• Remove the upper and lower baffle, see Section XX

PR8065

Flue collar

Upper &

Lower Baffle

Rear bricks

Blanking

cover

• Remove the top bricks, see Section 5

• Remove the flue collar using a 10mm A/F spanner/socket

wrench to remove the 4 fixing bolts including the 2 flanged

spacers

• Remove the blanking plate using a 10mm A/F

spanner/socket wrench to take out the 4 bolts