INsTAllATIoN INsTRUCTIoNs
3.5 Typical Top Flue Pipe Installation
600mm
minimum
PR8053
135 Elbow with access cover
600mm
minimum
All models
Connection to chimney
as detailed in Building
Regulations
Flue pipe x 612 long
1000mm
max
unsupported
4. ReMoVAl oF THe loG GUARd
4.1 To remove the Log guard:
• Lift Log Guard clear of the supporting brackets
• Rotate to clear the sides of the door opening.
do not use appliance without the log guard in position.
PR8114
5. FITTING ANd ReMoVAl oF
THe BAFFles
No tools are required.
5.1 To maintain efficient combustion the Riva Stove is fitted
with a twin baffle system, consisting of upper and lower
baffles.
5.2 First remove the Log Guard from the stove to give access to
the firebox.
3.3 Fitting the flue collar and blanking plate to the top
PR8066
Blanking Cover
Flue Collar
Fire Cement
Flanged Collar
• Fit the blanking plate to the top flue outlet
• Use the 4 bolts (including the 2 flanged spacers as
shown), seal to the firebox as shown using fire cement
• Fit the flue collar to the rear flue outlet using the 4 bolts
from the cover plate
• Seal to the firebox using fire cement
• Do not replace the top, rear or centre firebricks
• Re-install upper and rear baffle
3.4 The following flue pipe is available to ensure safe
installation:
5" Tee
Stovax Product Code 4516
6" Tee
Stovax Product Code 4616
5" 135o Bend
Stovax Product Code 4512
6" 135o Bend
Stovax Product Code 4512
5" Flue Pipe x 612mm long
Stovax Product Code 4501
6" Flue Pipe x 612mm Long
Stovax Product Code 4601
PR8055
Self-tapping screw
Tee with cap
Cap
Seal collar with fire cement
All models