S-Registers are accessed using the S command (ATSn=x). The S-Registers supported by the
MT5634ZLX/E are described below.

S-Reg.

Values Default Description

S0=

0 - 255 000

S0 sets the number of the rings required before the modem
automatically answers a call. Set S0=0” to disable auto-answer
mode.

S1=

0 - 255 000

S1 counts the incoming rings and stores the value to this register.
The value of this register is incremented with each ring. If no rings
occur over an 8 sec. interval, this register is cleared. User can read
but should not change this value.

S2=

0 - 255 043

S2 holds the decimal value of the ASCII character used as the
escape character. The default value (043) corresponds to an ASCII
character “+”. A value of 128 to 255 disables the escape process
(i.e., no escape character is recognized).

S3=

0 - 127 013

S3 holds the decimal value of the Carriage Return <CR> character
used as the command line and result code terminator. Pertains to
asynchronous operation only.

S4=

0 - 127 010

S4 holds the decimal value of the character recognized as a line
feed. The line feed control character is output after the carriage
return control character if verbose result code are used.

S5=

0 - 32, 127

S5 holds the decimal value of the character recognized as a
backspace. The modem will not recognize the backspace character
if this register is set to a value greater than 32008.

S6=

S6 sets the length of time, in seconds, that the modem must wait
(minimum 2 seconds even if the value is less than 2) after going off-
hook before dialing the first digit of the telephone number.

S7=

S7 sets the time, in seconds, that the modem must wait before
hanging up because carrier is not detected

S8=

0 - 65

002

S8 sets the time, in seconds, that the modem must pause when the
“,” dial modifier is encountered in the dial string.

S10=

1 - 255 020

S10 sets the length of time, in tenths of a second, that the modem
waits before hanging up after a loss of carrier.

S11=

50 - 150 095

S11 sets the DTMF duration and inter digit delay. Sets the duration
and spacing, in mini-seconds, in DTMF touch tine dialing.

S28=

0 - 255 001

V.34 modulation enable/disable:
0: disabled
1- 255: enabled

S30=

0 - 90

000

Inactivity timer. S30 sets length of time, in minutes, that the modem
counts when there is no data flow in or out the DTE serial port. A
connection is disengaged when the counter reaches the preset
value. Set S30 =0 to disable inactivity timer. For buffer mode only.