Active charcoal filter

The active charcoal filter is needed for
recirculation mode. It is not used for
vented extraction.
The hood is preset for vented extrac-
tion, the filter hour counter for the ac-
tive charcoal filter is set to ”unlimited”.

For recirculation mode the filter timer
needs to be set to the required time:

Use the On/Off button to turn the fan
off.

or

Push the deflector plate in.

Press the Delayed Shut Down button
and the active charcoal filter button
simultaneously.

The indicator for the active charcoal fil-
ter button and one of the indicators be-
tween the

/

+

buttons will flash.

The indicators between the

/

+

buttons

show the time which has been set:
1st indicator from left = 120 hours
2nd indicator from left = 180 hours
3rd indicator from left = 240 hours
4th indicator from left = unlimited

Use the

/

+

buttons to select the

desired time.

Confirm the programming by press-
ing the active charcoal filter button.

If the programming is not confirmed
within 4 minutes the hood will auto-
matically revert to the ”old” data.