Reducing collar 29, Runners 29, Reducing collar 3. runners – Miele DA 337 I User Manual

Page 28: Installation, Non-return flap

Advertising
background image

Installation procedure

1. Non-return flap (if needed)

2. Reducing collar (if needed)

3. Fit the runners in the cabinet

4. Hang and align the cabinet door

5. Position the appliance in the cabinet

6. Align the height of the appliance

7. Align the depth of the appliance

8. Fit the side spacers, the spacer
strip, and the light cover

9. Set up for air extraction or recircula-
tion

10. Connect to the electrical supply

Prepare the vent connection/ vent
socket for air extraction or recirculation
before installation.

1. Non-return flap

Air extraction with integrated fan

Fit the non-return flap into the vent
socket so that the flaps can open up-
wards.
(This is not necessary if the ducting
system is already fitted with a non re-
turn flap, e.g. wall vent).

Air extraction with external fan

The non-return flap is integrated into
the vent socket.

Recirculation mode

When used in recirculation mode it is
not necessary to fit a non-return flap.

Installation

28