Maintenance – Marantz VP-12S1s User Manual

Page 25

Advertising
background image

21

ADDITIONAL INFORMATION

ENGLISH

CAUTION:

• Do not touch the lamp and the lamp unit immediately. It

will be extremely hot. Allow at least one hour for the lamp
to cool down before handling.

• Do not loosen any screws except for those mentioned

below.

• The lamp may break if handled improperly.
• Do not use other than a Marantz replacement lamp unit.

7

How to replace the Lamp Unit

WARNING:

• The lamp itself may get hot. Be careful when handling.

1.

Press the POWER key to turn the projector off.

2.

Unplug the AC power cord.

3.

Wait at least one hour for the lamp and lamp unit to cool
down.

4.

Read the caution and warning labels on the unit.

If the lens becomes dirty or smudged, clean it with a soft dry
cloth. Use optical lens cleaners only which are approved for
eyeglasses or cameras. Do not use a dampen cloth, detergent
solution, or thinner. It may damage the lens and remain as
stains.

When replacement parts are required, be sure to inform a
Marantz authorized service center. Use only replacement
parts specified by Marantz. Unauthorized substitutions may
result in fire, electric shock, or other hazards.
And, the warranty may not be guaranteed.

7 Lamp Unit

: LU-12VPS1

7 Ceiling Mount KIT : RM-12VPS1

7 Lens

: LN-12VPS1

CAUTION:

• For ceiling installation, consult with the Marantz Authorized

dealer.

MAINTENANCE

Replacing Lamp Unit

Cleaning the lens

Replacement parts

Optional accessories

MODEL NO. VP-12S1 / U1S

AC 120V 60HZ 2.0A

SERIAL NO.

CAUTION :

HIGH PRESSURE LAMP

MAY EXPLODED IF IMPROPERLY HANDLED.
REFER SERVICING TO QUALIFIED SERVICE
PERSONNEL.

ATTENTION :

LA LAMPE SOUS

HAUTE PRESSION PEUT SI ELLE, N'EST
PAS MANIPULEE CORRECTEMENT,
CONFIER L'OPERATION A UN
PERSONNEL D'ENTRETIEN QUALIFIE.

CAUTION HOT :

UNPLUG

THE POWER CORD AND WAIT
60 MINUTES BEFORE CHARGING
THE LAMP.

ATTENTION CHAUD :

DEBRANCER LE CORD ON
D'ALOMENTION ET ATENDER
60 MINUTES AVANT DE
CHANGER LAMPE.

M

MODEL NO. VP-12S1 / N1S

MADE IN JAPAN

FABRIQUE AU JAPON

AC 120V 60H

Z

2.0W

SERIAL NO.

CAUTION :

HIGH PRESSURE LAMP

MAY EXPLODED IF IMPROPERLY HANDLED.
REFER SERVICING TO QUALIFIED SERVICE
PERSONNEL.

ATTENTION :

LA LAMPE SOUS

HAUTE PRESSION PEUT SI ELLE, N'EST
PAS MANIPULEE CORRECTEMENT,
CONFIER L'OPERATION A UN
PERSONNEL D'ENTRETIEN QUALIFIE.

CAUTION HOT :

UNPLUG

THE POWER CORD AND WAIT
60 MINUTES BEFORE CHARGING
THE LAMP.

ATTENTION CHAUD :

DEBRANCER LE CORD ON
D'ALOMENTION ET ATENDER
60 MINUTES AVANT DE
CHANGER LAMPE.

5.

Loosen the lamp cover securing screw.

6.

Remove the lamp cover.

7.

Loosen the two lamp housing screws.
(This projector has a safety switch.)

8.

Hold the handle then pull the lamp unit to remove.

9.

Install the new lamp unit.

10.

Secure the lamp unit with the two screws.

11.

Close the lamp cover and secure it with a screw driver.

Lamp cover

Advertising
This manual is related to the following products: