Multiquip MQPower Whisperwatt Series DCA-300SSK User Manual

Page 37

Advertising
background image

DCA-300SSK SERIES — PARTS AND OPERATION MANUAL (STD)— REV. #4 (03/27/06) — PAGE 37

DCA-300SSK SERIES — GEN. START-UP PROCEDURE (MANUAL)

Figure 42. Engine Enclosure Doors

Steps 1 thru 20 are referenced
for Engine Operating Panel S/N
3701673 and below. See Figure
40 below. This unit has an

igni-

tion switch and a throttle
handle
.

NOTE

Figure 40. Engine Operating Panel

S/N 3701673 and Below

1. Place the

main, G.F.C.I. and aux. circuit breakers (Figure 42)

in the “OFF” position prior to starting the engine.

Figure 42. Main, Aux. and GFCI

Circuit Breakers (OFF)

The engine's exhaust contains harmful emissions.
ALWAYS have adequate ventilation when operating.
Direct exhaust away from nearby personnel.

CAUTION - LETHAL EXHAUST HAZARD

NEVER! manually start the engine with the main, GFCI
or

auxiliary circuit breakers in the ON (closed) position.

WARNING - STARTING THE GENERATOR

2. Make sure the the

voltage change-over board has

been configured for the desired output voltage.

3. Connect the load to the

UVWO terminals or auxiliary

receptacles as shown in Figure 12. These load
connection points can be found on the output terminal
panel. To gain access to the UVWO terminals or other
power receptacles, unlock the access cover and lift the
door.

4. Tighten terminal nuts securely to prevent load wires from

slipping out

5. Close all engine enclosure doors (Figure 42).

BEFORE STARTING (S/N 3701673 and below)

Advertising