Multiquip MQPower Whisperwatt Series DCA-300SSK User Manual

Page 39

Advertising
background image

DCA-300SSK SERIES — PARTS AND OPERATION MANUAL (STD)— REV. #4 (03/27/06) — PAGE 39

DCA-300SSK SERIES — GENERATOR START-UP PROCEDURE (MANUAL)

15. The engine oil pressure gauge (Figure 52) will indicate

the oil pressure (kg/ cm

2

)

of the engine. Under normal

operating conditions the oil pressure is approximately

Figure 52. Oil Pressure Gauge

Figure 54. Engine Tachometer Gauge

17. The

tachometer gauge (Figure 54) will indicate the

speed of the engine when the generator is operating.
Under normal operating conditions this speed is
approximately 1800 RPM’s.

16. The

coolant temperature gauge (Figure 53) will indicate

the coolant temperature. Under normal operating
conditions the coolant temperature should be between
165 and 215 degrees Fahrenheit (

Green Zone).

Figure 53. Coolant Temperature Gauge

WATER

TEMP

0

4

8

kg/cm2

ENGINE OIL PRESSURE

Figure 55. Main, Aux. and GFCI

Circuit Breakers (ON)

18. Place the

main, GFCI, and aux. circuit breakers in the

ON” position (Figure 55).

19. Observe the generator's ammeter (Figure 56) and verify

it reads the anticipated amount of current with respect
to the load. The ammeter will only display a current
reading if a load is in use.

20. The generator will run until manually stopped or an

abnormal condition occurs.

Figure 56. Ammeter (Load)

Advertising
This manual is related to the following products: