Figure 50. Voltage Adjust Control Knob

Figure 51. Ammeter (No Load)

14. The ammeter (Figure 51) will indicate zero amps with no

load applied. When a load is applied, the ammeter will
indicate the amount of current that the load is drawing
from the generator.

13. The generator's AC-voltmeter (Figure 49) will display the

generator’s output in VOLTS. If the voltage is not within
the specified tolerance, use the voltage adjustment
control knob (Figure 50) to increase or decrease the
desired voltage.

Figure 49. Voltmeter

Figure 45. Pre-Heat Button/ Lamp

9. Place the

engine throttle control in the “LOW” position

(Figure 46).

Figure 48. Frequency Meter (Hz)

Figure 47 Engine Ignition Switch

10. Turn the ignition key to the “START” position (Figure 47)

and listen for the engine to begin cranking. After the
engine starts release the ignition key.

Figure 46. Engine Throttle Control

11. Once the engine has started, let it run for 3-5 minutes,

then turn the throttle handle control (Figure 46) to the
HIGH” position.

7. When starting the generator in COLD weather conditions,

turn the

ignition key to the “PREHEAT ” position (Figure 44).

Figure 44. Ignition Switch (Pre-Heat)

12. The generator's frequency meter (Figure 48) should be

displaying the 60 cycle output frequency in HERTZ.

8. Press and hold the engine preheat button (Figure 45)

until the preheat lamp is lit (ON).

6. Set the

battery ON/OFF switch (Figure 43) to the “ON

position.

Figure 43. Battery ON/OFF Switch

DCA-300SSK SERIES — GENERATOR START-UP PROCEDURE (MANUAL)

Pre-Heat

Lamp

Pre-Heat

Button