PAGE 42 — DCA-300SSK SERIES — PARTS AND OPERATION MANUAL (STD) — REV. #4 (03/27/06)

Figure 69. Ignition Key Switch (STOP position)

Engine Shutdown Ignition Key (Up to S/N 3701673)

To shutdown the generator use the following procedure:

1. Place both the MAIN, GFCI and LOAD circuit breakers

(Figure 67) to the "OFF position".

3. Let the engine cool by running it for 3-5 minutes with no

load applied.

5. Remove all loads from the generator.

2. Place the throttle control (Figure 68) in the “LOW” position.

Figure 68. Engine Throttle Control

4. Place the ignition key (Figure 69) in the “STOP” position.

Figure 67. Main, Aux. and GFCI

Circuit Breakers (OFF)

Engine Shutdown Controller (S/N 3701674~)

To shutdown the generator use the following procedure:

1. Place both the MAIN, GFCI and LOAD circuit breakers

as shown in Figure 67 to the "OFF position".

2. Place the engine speed switch in the “

LOW ” position

(Figure 71).

Figure 71. Engine Speed Switch (High)

3. Let the engine cool by running it for 3-5 minutes with no

load applied.

4. Place the Auto-Manual/Off/Reset switch (Figure 72) to

the

OFF/Reset position.

Figure 72. Auto-Manual Off/Reset Switch

5. Verify that the

all status LED on the MPEC display are

"OFF" (not lit).

6. Remove all loads from the generator.

Emergency Shutdown Procedure

1. PUSH inward the RED emergency stop button located

on the

engine operating panel (Figure 70) to turn off

the generator in the event of an emergency. This button
is located on either Engine Operating Panel.

Figure 70. Emergency Stop Button

DCA-300SSK SERIES — GEN. SHUT-DOWN PROCEDURE (MANUAL)

NOTE

To disengage the emergency
stop function, pull the
emergency stop button outward
to its original position. This will
allow the generator to operate
normally. Remember the

generator will not start if the emergency stop button is
engaged.

WARNING - SHUTTING DOWN THE GENERATOR

NEVER stop the engine suddenly except in an emergency.
DO NOT use the emergency stop switch a as method of
shutting down the generator. This switch is ONLY to be
used in the event of an emergency.