Multi-Tech Systems MTASR3-200 User Manual

Page 66

Advertising
background image

RASFinder User Guide

MTASR3-200

66

Command:

\G

n

Modem Port Flow Control

Values:

n = 0

Default:

0

Description:

\G0

Returns an

OK for backward compatibility with some software.

\G1

Not supported—responds ERROR.

Command:

\J

n

Data Buffer Control

Values:

n = 0

Default:

0

Description:

\J0

Enable data buffer—serial port speed is independent of connect speed.

\J1

Not supported—responds ERROR.

Command:

\K

n

Set Break Control

Values:

n = 5

Default:

5

Description:

\K5

Modem sends break signal received from the DTE to the remote modem.

Command:

\N

n

Error Correction Mode Selection

Values:

n = 0–5, or 7

Default:

3

Description:

\N0

Non-error correction mode with data buffering (same as

&Q6).

\N1

Direct mode.

\N2

MNP reliable mode.

\N3

V.42/MNP auto-reliable mode.

\N4

V.42 reliable mode.

\N5

V.42, MNP, or non-error correction (same as

\N3).

\N7

V.42, MNP, or non-error correction (same as

\N3).

Command:

\Q

n

Local Flow Control Selection

Values:

n = 0, 1, or 3

Default:

3

Description:

\Q0

Disable flow control (same as

&K0).

\Q1

XON/XOFF software flow control (same as

&K4).

\Q2

CTS-only flow control. Not supported—responds ERROR.

\Q3

RTS/CTS hardware flow control (same as

&K3).

Command:

\T

n

Inactivity Timer

Values:

n = 0–255

Default:

n/a

Description:

\Tn

Inactivity timer setting contingent on either \T value or S-Register S30 value (e.g.,
AT\T45&W0<cr> configures in parallel ATS30=45&W0<cr>), and vice versa.

Command:

\V

n

Protocol Result Code

Values:

n = 0 or 1

Default:

1

Description:

\V0

Disable protocol result code appended to DCE speed.

\V1

Enable protocol result code appended to DCE speed.

Command:

\X

n

XON/XOFF Pass-Through

Values:

n = 0 or 1

Defaults:

0

Description:

\X0

Respond to and discard XON/XOFF characters.

\X1

Not supported—responds ERROR.

Command:

-C

n

Data Calling Tone

Values:

n = 0 or 1

Defaults:

0

Description:

-C0

Disable V.25 data calling tone.

-C1

Enable V.25 data calling tone.

Advertising