PAGE 22 — MAYCO ST-45HRM CE PUMP — OPERATION & PARTS MANUAL — REV. #0 (02/23/04)

ST-45HRM CE CONCRETE PUMP— CONTROL BOX COMPONENTS

Figure 8. Pump Control Box Components

1.

Engine Tachometer – Monitors the engine RPM’s and
hours of operation for the engine.

2.

Emergency Stop Button – Press emergency stop button
to stop pump in an emergency. Turn knob counter clockwise
to disengage the stop button.

3.

Hourmeter – Display's the number of hours the pump has
been in use.

4.

Ignition Switch – Insert the ignition key here to start the
engine. Turn the key clockwise to the “ON“ position, then
continue turning clockwise to the “START“ position and
release. To stop the engine turn the key fully counter-
clockwise to the “STOP“ position.

5.

Battery Indicator Lamp– Indicates a low battery charge.
Replace or charge battery.

NEVER operate the ST-45 when

this lamp is on.

6.

Oil Pressure Indicator Lamp– When lit, indicates correct
operational pressure for running the ST-45. NEVER operate
the ST-45 if this lamp is off.

7.

Air Filter Indicator Lamp – Indicates the engine air filter
is functioning properly. NEVER operate the ST-45 if this
lamp is off.

8.

Direction Control Switch– This 2 position switch controls
the direction of flow for any mix in the pump. The

center

position sets the pumping direction to forward and the

right

most

position sets the pumping direction to reverse.

9.

Pump Operation Switch– This 2 position switch controls
the operation of the pumping components and engine. The

center

position allows the operation of the pump and

engine and the

right most

position allows only the engine

to operate.

10. Pressure Test Switch– Activates a self-diagnostic routine

which tests the pressure of the pumping system, which can
be read on the Pumping Pressure Gauge.

11. Pumping Control Switch – This 3-position switch controls

the pumping of the pump. The

left most

position is for use

with the remote control unit, the

center

position is for

normal pumping operation, and the

right most

position

(OFF) prevents pumping.

12. Cooling Fan Switch – If hydraulic oil temperature exeeds

23.9° C (75° F), set the pump operation switch to engine
and turn the cooling fan switch to the right most position to
activate cooling fan.

13. Remote Cable Connector – Insert the remote control input

cable into this connector.