18. Down-Hill Pumping – can be difficult on some jobs. The

slurry procedure would be the same as explained on the
pages titled Operating Suggestions. It is suggested that a
sponge 5 cm x 10 cm x 15 cm (2”x 4”x 6”) be placed in the
hose before the start of pumping. Wet the sponge before
placing it in the hose.

The reason for using the wet sponge is to keep the slurry from
running too far ahead of the concrete and so reducing the
possibility of separation. When the pump is stopped, the
material can flow slowly down, due to gravity, and cause the
hose to collapse.

When pumping is resumed, you can expect blockage at the
point of hose collapse. To prevent this from happening, the
hose can be “kinked off” at the discharge end when the pump
is stopped to prevent the gravity flow of the material in the
hose.

The use of stiffer mixes when pumping down-hill will de-
crease gravity flow of the material in the hose and will assure
a smoother operation between the cam roller bearing and
cam plate. As with any job, make sure that the hose and the
couplings are in good workable shape.

If, for any reason, the mix should set up in the system, the
following procedure (

E through H

) is suggested:

E. Disconnect the hose from the pump and wash the pump

out immediately.

F.

Reconnect the hose and fill the hopper with water.

G. Reconnect the hose and fill the hopper with water. DO

NOT try to push all the concrete out of all of the hose
lines at one time.

For example: If you had 61 meters (200 ft.) of system out,
you would disconnect each hose. Clean it out by push-
ing water through the first hose off the pump, then
continue progressing through all the hoses, until all the
system is clean.

H. If waiting time is excessive, it would be wise to wash out

the pump and hoses and start over when the new truck
arrives. This can be avoided by being observant to the
pump and system, also taking into consideration the
above factors (E through H) affecting the mix.

17. If it is necessary to wait 1/2 hour or more for another load

of concrete, and to prevent setting of the mix in the system,
it is advisable to consider the following factors
(

A through

D

) affecting the concrete :

A. How old is the concrete?

B. Is there an accelerator, calcium chloride, red label, etc.,

in the concrete?

C. Temperature of the day, 27° C (80° F), 32° C (90° F)?

D. How much system you have out and how stiff was the mix

you were pumping?

When disconnecting hoses, use
EXTREME CAUTION! The hose is
under pressure!

NOTE

Make sure the accumulator pressure gauge
reads ZERO psi. prior to performing any
maitinance or inspection.

D. Carefully knock the end of the hose away from the

reducer.

E. Chip the concrete out of the reducer with the pry bar.

F.

Remove the reducer. From the discharge end, chip the
concrete out of the shuttle tube with the pry-bar. If
concrete cannot be loosened from the outlet of the
shuttle tube, remove the clean-out plug on the bottom
of the hopper to discharge the concrete.

G. The senior operator may then remove the inspection

cover plate from the shuttle tube by using a long
extension wrench and the 61 cm (24-inch) pry bar.

H. Chip the blockage out with the pry-bar.

I.

Flush the shuttle tube with water.

J.

Replace and seal the inspection cover plate on the
shuttle tube.

K. Before resuming operation of the pump, perform the

“Reverse” Pumping Procedure to relieve pressure on
the shuttle tubes.

WARNING