MAYCO ST-45HRM CE PUMP — OPERATION & PARTS MANUAL — REV. #0 (02/23/04) — PAGE 53

ST-45HRM CE CONCRETE PUMP— MAINTENANCE (PUMP)

ST45 PRESSURE SETTING SEQUENCE

To set

maximum

pump pressure:

1.

With the engine turned “OFF”, loosen the 6.4 mm (1/4-
inch) hydraulic hose attached to the compensator valve
located on the top of the Main Delta Q Pump.

2.

Loosen the

jam nut

located on the end of the compensator

valve (Figure 50).

3.

Turn the

compensator adjustment nut

(Figure 50)

clockwise

until tight. Tighten the 6.4 mm (1/4-inch) hose

leading to the compensator.

4.

Start the engine and loosen the jam nut located on the

maximum relief valve cartridge

(Figure 51).

5.

Run the engine at maximum RPM (2,550) and turn the
volume control knob

counter-clockwise

to maximum

volume position (Figure 51).

Figure 50. Compensator Valve

MAXIMUM RELIEF

VALVE CARTRIDGE

JAM NUT

MAIN

RELIEF VALVE

VOLUME

CONTROL

Figure 51. Hydraulic Drive Pump Manifold

6.

On the control box, turn the

pump control switch

(Figure

22) and the

test switch

(Figure 31) to the “ON” position.

Using an allen wrench, adjust the

main relief valve

(Figure

45) to 24.13 mPa (3,500 PSI). The reading can be taken
from the

pumping pressure gauge

(Figure 52).

7.

Hold the main relief valve adjusting bolt with a wrench and
tighten the jam nut. Using the test switch, double check the
pressure reading to make sure the setting has not changed.

Figure 52. Pumping Pressure Gauge

8.

Turn the engine off and loosen the hose from the
compensator valve. Loosen the jam nut and turn the

compensator adjustment nut

(Figure 50)

counter-

clockwise

½

turn. Tighten the 6.4 mm (1/4-inch) hydraulic

hose.

9.

Start engine and run at maximum RPM with volume control
at maximum volume (fully

counter-clockwise

). Turn the

pressure test switch

(Figure 31) to the “ON” position.

The pumping pressure gauge should now read 22.75
mPa (3300 PSI)
. It may be necessary to repeat the above
steps to achieve the proper pressure settings. After the
adjustment, make sure the compensator valve jam nut is
locked tight.