REAR STABILIZER STAND

To reduce excessive vibration and rocking of the ST-45 Concrete
Pump, set the rear stabilizers as follows:

15. Locate both the left and right rear stabilizer stands

(Figure 16).

16. Remove the

cotter pin

from the handle tee bolt eye, and

then

pull

the handle tee to release the stabilizer stand (Figure

17).

17. Position both rear stabilizers stands on firm (not loose)

level

ground (Figure 18).

18. Align the hole on the stabilizer stand with the hole on the

frame body and

insert

handle tee bolt.

19. Insert the cotter pin into handle tee bolt eye to lock the

stabilizer stand.

ST-45HRM CE CONCRETE PUMP— INSPECTION

14. If the hydraulic oil level is low, remove the cap just above the

oil level sight glass (Figure 15) and add the correct amount
of hydraulic oil to bring the hydraulic oil level to a normal
safe operating level. (Use Shell oil Tellus 68 or Mobil oil
DFE26).

Figure 15. Hydraulic Oil Filler Hole

Figure 16. Locatiing Rear Stabilizer Stands

Figure 17. Rear Stablizer Stand

Figure 18. Rear Stablizer Stand Deployment

Advertising