Trunk – MicroNet Technology SP1659P User Manual

Page 114

Advertising
background image

SP1659P(time)# set ntp 210.59.157.10 8
SP1659P(time)#


show

Syntax: show

Description:

To show the time configuration, including “Current Time”, “NTP Server”,” Timezone”,

” Daylight Saving”,” Daylight Saving Start” and “Daylight Saving End”

Argument: None

Possible value: None

Example:

SP1659P(time)# show
Current Time

: Thu Thu 14 15:04:03 2005

NTP

Server :

209.81.9.7

Timezone

:

GMT+8:00

Day light Saving

: 0 Hours

Day light Saving Start

: Mth: 1 Day: 1 Hour: 0

Day light Saving End

: Mth: 1 Day: 1 Hour: 0

SP1659P(time)#

4.3.27 trunk

del trunk

Syntax: del trunk <port-range>

Description: To delete the trunk port.

Argument: <port-range>: port range, syntax 1,5-7, available from 1 to 24

Possible value: <port-range>: 1 to 24

Example:

SP1659P(trunk)# del trunk 1
SP1659P(trunk)#

set priority

Syntax: set priority <range>

Description: To set up the LACP system priority.

Argument: <range>: available from 1 to 65535.

Possible value: <range>: 1 to 65535, default: 32768

Example:

SP1659P(trunk)# set priority 33333
SP1659P(trunk)#

set hash

Syntax: set hash <method>

Description: To set up trunk hash method.

Argument:

<method>: lacp hash method

0: DA and SA

1: SA

2: DA

Possible value: <method>: 0~2

Example:

113

Advertising