Diag, Firmware – MicroNet Technology SP1659P User Manual

Page 83

Advertising
background image

Example:

SP1659P(dhcp-boot)# show
Dhcp Boot : Enable
Second : 10

4.3.8 diag

diag

Syntax: diag

Description: Diag is used to test whether UART, DRAM, Flash and EEPROM is normal or not.

Argument: None.

Possible value: None.

Example:

SP1659P(diag)# diag
EEPROM Test : OK
UART Test : OK
DRAM Test : OK
Flash Test : OK

loopback

Syntax: Loopback

Description: For Internal/External Loopback Test.

Argument: None.

Possible value: None.

Example:

SP1659P(diag)# loopback
Internal Loopback Test : OK

External Loopback Test : Port 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 Fail

ping

Syntax: ping <ip>

Description: To confirm that whether the remote end-station or switch itself is alive or not.

Argument: [ip] : ip address or domain name

Possible value: IP address, e.g. 192.168.2.65 or domain name, e.g. tw.yahoo.com

Example:

SP1659P(diag)# ping 192.168.1.115
Gateway : 192.168.1.253
192.168.1.115 is alive.

4.3.9 firmware

set upgrade-path

Syntax: set upgrade-path <filepath>

Description: To set up the image fie that will be upgraded.

Argument: <filepath>: upgrade file path

Possible value: <filepath>: upgrade file path

Example:

SP1659P(firmware)# set upgrade-path sp1659P_v0.92.bin.gz

82