DCT3080 Installation Manual

34

ƒ

When the LED display is blank, the terminal is ready for initialization

and service authorization using the addressable controller. Verify that
the terminal is powered up or reset within two minutes of a
completed download.

Boot Cycle Error Codes

If hardware or software problems occur, the terminal displays error
codes on the LED display.

125H

Table 2-5 lists error codes that can occur

during boot cycle startup:

Table 2-5
Boot cycle error codes

Code Description

When Error Occurs

Action Required

Eb
01

Object failed
validation

After the LED displays dl,
indicating validation check
failed

Contact headend
operator

Eb
02

Download
time-out

After cycling twice through the
OOB frequencies

None

Eb
03

Flash erase
failed

After software object
download complete and EF is
displayed

Replace the terminal

Eb
04

Flash
programming
failed

After software object
download complete and FP is
displayed

Contact headend
operator

Eb
05

Invalid DLC
frequency

After the LED displays dl,
indicating validation check
failed

Contact headend
operator

Eb
06

Hardware
initialization
failed

After plugging the terminal
into an electrical outlet to
begin the boot cycle

Replace the terminal

Advertising