Operational check for the remote control, Dct3080 installation manual – Motorola DCT3080 User Manual

Page 41

Advertising
background image

DCT3080 Installation Manual

35

Code Description

When Error Occurs

Action Required

Eb
07

Object failed
validation

After software object
download complete and FP is
displayed

After a successful software
object download and the
terminal is reset

Contact the headend
operator

No action required
because the terminal
repeats the software
object download

Eb
08

Reserved

None

Eb
09

Check failed

Reset within two minutes of a
complete software object
download

No action required
because the terminal
repeats software
object download
process

Eb
10

SUDB
recreation

After plugging the terminal
into an electrical outlet to
begin the boot cycle

None

Eb
11

Failed to lock
OOB frequency

After cycling twice through the
OOB frequencies (LED then
displays Eb 02, indicating
the software object download
was unsuccessful.)

Ensure proper cable
connections

Eb
12

No COAC
message
received

After cycling twice through the
OOB frequencies (LED then
displays Eb 02, indicating
the software object download
was unsuccessful.)

Contact headend
operator

Eb
13

No DLC
message
received

After cycling twice through the
OOB frequencies (LED then
displays Eb 02, indicating
the software object download
was unsuccessful.)

Contact headend
operator

Eb
14

Bad object type
or class

After the LED displays dl,
indicating failed during
attempted download

Contact headend
operator

Eb15 No matching

After cycling twice through the Contact headend

Advertising