Tighten strain relief screw, Remove center silver-colored terminal block screw – Maytag W10131619A User Manual

Page 12

Advertising
background image

12

When connecting to the terminal block, place the hooked end of the wire under the screw of
the terminal block (hook facing right), squeeze hooked end together and tighten screw, as
shown.

1. Loosen or remove center silver-colored terminal block screw.
2. Place the hooked end of the neutral wire (white or center wire) of power supply cable

under the center screw of terminal block (hook facing right). Squeeze hooked end
together. Tighten screw.

B

C

D

E

A

A. Neutral ground wire

B. External ground conductor screw

C. Center silver-colored terminal block screw

D. Neutral wire (white or center wire)

E. ¾" (19 mm) UL listed strain relief

3. Place the hooked ends of the other power supply cable wires under the outer terminal

block screws (hooks facing right). Squeeze hooked ends together. Tighten screws.

4. Tighten strain relief screw.

5. Insert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-

down screw.

6. You have completed your electrical connections. Now go to “Venting Requirements.”

Optional 3-wire connection

Use for direct wire or power supply cord where local codes do not permit connecting
cabinet-ground conductor to neutral wire.
1.
Remove center silver-colored terminal block screw.
2. Remove neutral ground wire from external ground conductor screw. Connect neutral

ground wire and the neutral wire (white or center wire) of power supply cord/cable under
center, silver-colored terminal block screw. Tighten screw.

A

B C

D

E

F

A. External ground conductor screw

B. Neutral ground wire

C. Center silver-colored terminal block screw

D. Neutral wire (white or center wire)

E. ¾" (19 mm) UL listed strain relief
F. Grounding path determined by a qualified electrician

3. Connect the other wires to outer terminal block screws. Tighten screws.

Advertising