Electrical connection, Disconnect power, Install strain relief – Maytag W10131619A User Manual
Page 7: Style 1: power supply cord strain relief, Warning
7
Electrical Connection
Power Supply Cord
WARNING
Fire Hazard
Use a new UL listed 30 amp power supply cord.
Use a UL listed strain relief.
Disconnect power before making electrical connections.
Neutral wire (white or center wire) must be connected
to center silver terminal.
Ground wire (green or bare wire) must be connected to
green ground connector.
Remaining 2 supply wires must be connected to
remaining 2 gold terminals.
Securely tighten all electrical connections.
Failure to do so can result in death, fire, or
electrical shock.
Direct Wire
WARNING
Fire Hazard
Use 10 gauge solid copper wire.
Use a UL listed strain relief.
Disconnect power before making electrical connections.
Neutral wire (white or center wire) must be connected
to center silver terminal.
Ground wire (green or bare wire) must be connected to
green ground connector.
Remaining 2 supply wires must be connected to
remaining 2 gold terminals.
Securely tighten all electrical connections.
Failure to do so can result in death, fire, or
electrical shock.
1. Disconnect power.
2. Remove the hold-down screw and terminal block cover.
A B
E
F
C
D
A. Terminal block cover
B. External ground conductor screw
C. Center, silver-colored terminal
block screw
D. Hold-down screw location
E. Neutral ground wire
F. Hole below terminal block opening
3. Install strain relief.
Style 1: Power supply cord strain relief
■
Remove the screws from a ¾" (19 mm) UL listed strain relief (UL marking on strain
relief). Put the tabs of the two clamp sections into the hole below the terminal block
opening so that one tab is pointing up and the other is pointing down, and hold in
place. Tighten strain relief screws just enough to hold the two clamp sections together.
A
B
C
D
A. Strain relief tab pointing up
B. Hole below terminal block opening
C. Clamp section
D. Strain relief tab pointing down