OM-228 322 Page 19

5-12. Motor Board DIP Switch Settings

Position Settings And Results For DIP Switch S1 On PC1 And PC101

Remove wrapper.
1

DIP Switch S1 On Motor

Board PC1 and PC101

S1-1
Run-In enable or disable.
S1-2
Automatic Run-In versus Manual

Adjustment Run-in
Install wrapper when finished.

1

803 063 / Ref. 802 944

.

In the DIP switch S1 illustrations,
the elevated slider on each switch

is shown in white. For example,

the switches above are all in the

Off position.

Tools Needed:

1/4 in

This illustration shows

the factory setting of S1.

Left Side Motor

Control Board

PC101

Right Side Motor

Control Board PC1

P1

Run-In feature is not avail-

able. X - Means switch may

be in either position.

Run-In feature is available.

X - Means switch may be in either

position.

.

If 14 pin power cable from pow-
er source does not provide volt-

age and current feedback, Run-

In will automatically disable.

S1-1

S1-1

Run-In Disabled

Run-In Enabled

(Factory Default)

Run-In speed is approxi-

mately 1/2 weld wire feed

speed.

Run-In speed is set using poten-

tiometer P1 located on Motor

Board PC1.

.

P1 is a 25 turn potentiometer.

S1-1 And S1-2

S1-1 And S1-2

Automatic Run-In

(Factory Default)

Manually Adjusted Run-In