6-4. Trigger Hold Switch

1

Trigger Hold Switches

Trigger hold allows the operator to

weld without holding the gun trigger.

•

To use the trigger hold function,

place the trigger hold switch in

the On position.

•

The operator must hold the trig-

ger for a minimum of 2 seconds,

but not longer than 6 seconds be-

fore releasing it. Welding will con-

tinue when the trigger is re-

leased.

•

To stop welding, press the trigger

again.

1

Ref. 804 568-B

6-5. Voltage Control And Digital Meters

3

1

2

1

Voltmeter

Displays actual or preset voltage

from welding power source through

the 14−pin control cable.

.

Voltmeter will not display actu-
al or preset voltage if voltage

feedback is not provided

through the 14-pin control

cable.

2

Wire Speed Meter

Displays preset and actual wire

feed speed while welding.
Factory set to display inches per

minute. If display of meters per min-

ute is desired, see Section 5-12.
3

Voltage Controls

Use controls to adjust voltage out-

put of welding power source.

.

You can adjust the preset volt-
age display on the wire feeder

to match your power source’s

display by adjusting P2 on mo-

tor control board PC101 (left

side), and/or P2 on motor con-

trol board PC1 (right side). See

Section 7-3 for location of P2.

Ref. 804 567-B