4. trigger hold switch, 5. voltage control and digital meters, 1. routine maintenance – Miller Electric D-75S User Manual

Page 27: 2. brush inspection and replacement

Advertising
background image

OM-228 322 Page 23

SECTION 7 − MAINTENANCE

7-1. Routine Maintenance

Y Disconnect power before maintaining.

n = Check

~ = Clean

l = Replace

Reference

Every

3

Months

Section 5-2,

5-3

l Unreadable Labels

~ Weld Terminals

nl Weld Cable

nl Motor Brush

Section 5-2,

5-3

n 14-Pin Cord

n Gas Hose and Fittings

n Gun Cable

Every

6

Months

Or

Section 5-7

~ Inside Unit

~ Drive Rolls

7-2. Brush Inspection And Replacement

Y Do not disassemble motor field mag-

nets or injury/equipment damage may

occur.

1

Motor

2

Brush Cap

Remove brush cap.
3

Brush

Replace brush if it becomes chipped or bro-

ken, or if less than 1/4 in. (6.4 mm) of brush

material remains. Do not include spring boss

as part of the 1/4 in. measurement.
Install brush so that curved surface on end of

brush matches curve of motor, and secure

with cap.

137 390-B

Tools Needed:

1

2

3

Advertising
This manual is related to the following products: