3. diagnostics, 4. troubleshooting – Miller Electric D-75S User Manual

Page 29

Advertising
background image

OM-228 322 Page 25

7-4. Troubleshooting

Y Disconnect power before troubleshooting

Trouble

Remedy

Wire feeds, shielding gas flows, but

electrode wire is not energized.

Check cable connections. Check cables for continuity, and repair or replace cables if necessary

(see Section 5-3).

Wire feeder is on, display does not light

up, motor does not run, gas valve and

welding power source contactor do not

pull in.

Check and reset circuit breaker at welding power source.

Electrode wire feeding stops or feeds

erratically during welding.

Check gun trigger connection. See gun Owner’s Manual.

Check gun trigger. See gun Owner’s Manual.

Readjust hub tension and drive roll pressure (see Section 5-11).

Change to correct size drive roll (see Section 5-7 and Table 9-1).

Clean or replace dirty or worn drive roll.

Incorrect size or worn wire guides.

Replace contact tip or liner. See gun Owner’s Manual.

Remove weld spatter or foreign matter from around nozzle opening.

Check brushes in drive motor. If brush length is less than 1/4 inch, replace brushes.

Have Factory Authorized Service Agency check drive motor or motor control board PC1.

Motor runs slowly.

Check for correct input voltage.

Wire feeder power is on, displays light

up, feeder jogs, purges, but unit is in-

operative.

Check welding gun trigger leads for continuity, and repair leads or replace gun.

When triggered wire feeds but no gas,

no contactor.

If the welding arc does not establish in 3 seconds after the gun trigger is activated the unit will feed

wire, but turns off contactor and gas valve. If the gun trigger is still activated after two minutes, the

wire will stop feeding.

Advertising
This manual is related to the following products: