Murphy Centurion Configurable Controller CE-05171N User Manual

Page 32

Advertising
background image

CE-05171N page 32 of 44

6

6..3

3..1

14

4 L

Lu

ub

be

e N

No

o F

Fllo

ow

w S

Se

ett U

Up

p

User can view and edit Lube No Flow set up. There are two

levels to this menu as there are two possible adjustments per

No-Flow input. The user will select an input from the first menu

and press Setup/Enter. This will display the submenu for the

selected digital input if it is used for No-Flow monitoring.

Otherwise, the text label on the left side of the edit box will dis-

play “NOT IN USE”, and pressing Enter will have no effect.

At the submenu level, the user may adjust the expected tran-

sition frequency and the total cycles count (which relates to

the wear rate of the sensor).

6

6..3

3..1

15

5 L

Lu

ub

be

e N

No

o F

Fllo

ow

w S

Stta

attu

us

s

The user may view information about the No-Flow inputs. If a

digital input is designated for use as a No-Flow input, it will

display how much time elapsed before the last transition, and

how much time has elapsed since that transition. If the input

is not designated as a No-Flow input, there will be zeros dis-

played. Both values have a maximum value of 999.

6

6..3

3..1

16

6 S

Su

up

pe

err U

Us

se

err M

Me

en

nu

u

The Super User menu will only be visible if the Super User
password has been entered.

The first three selections (a – c) allow the user to temporarily
override the default behavior of the display. It may be helpful
to turn off a fault annunciation screen that prevents the view-
ing of information on operating status screens.

a

a)) Com Fail Disable
b

b)) Set up T/O Disable
c

c)) Config Fail disable

Note that the reset history commands do not permanently switch
to Yes when entered, but instead toggle back to NO after sending
the command to the controller.

TM

C

C

C

Lube No-Flow Setup Screen

___________________________________

LUBE NO-FLOW SETUP

NO-FLOW INPUT # 1

DI_1 NF

NO-FLOW INPUT # 2
NO-FLOW INPUT # 3
NO-FLOW INPUT # 4

NO-FLOW INPUT # 5

▼▲ ENTER-SUBMENU

MORE MENUS

___________________________________

___________________________________

TM

C

C

C

No-Flow # 1 Setup Screen

___________________________________

NO-FLOW INPUT # 1 SETUP

CYCLE TIME (SEC)

00010

TOTAL CYCLES (X100)

▼▲ ENTER-EDIT

ESC-EXIT THIS MENU

___________________________________

___________________________________

TM

C

C

C

Lube No-Flow Status Screen

___________________________________

LUBE NO-FLOW STATUS

CYCLE TIME-INPUT # 1

PREV 0 CURR 0

CYCLE TIME-INPUT # 2
CYCLE TIME-INPUT # 3
CYCLE TIME-INPUT # 4

CYCLE TIME-INPUT # 5

▼▲ CYCLE TIMER (SEC)

MORE MENUS

___________________________________

___________________________________

TM

C

C

C

Super User Menu Screen

___________________________________

SUPER USER MENU

COM FAIL DISABLE

NO

SETUP T/O DISABLE
CONFIG FAIL DISABLE
RESET FAULT HISTORY

RESET EVENT HISTORY

▼▲ ENTER-EDIT

MORE MENUS

___________________________________

___________________________________

Advertising